Computer room accessory products Home / Product Computer room accessory products

Deep View Wang Analog Matrix

Details

Product characteristics:

Each video has the function of overlapping the title of mixed graphics, Chinese and text graphics.

With the design of built-in IP control module and video server, the matrix host can be operated and switched to browse video images through IP network, and the camera and system can be accessed remotely (optionally).

The smallest 4U plug-in high-density module combination structure is adopted to facilitate combination expansion.

Keyboard permission to monitor and camera can be set; system can be partitioned.

Hot backup host selection design makes the host more stable.

There are surge protection measures and anti-lightning interference Design for the input and output ports of click/video and communication interfaces.

The click system can connect multiple multi-level matrices through RS485.

Bah supports virtual ball machine address function. The ball machine address can be modified at any time to facilitate engineering debugging.

Can control Haikang and Dahua hard disk video recorders.

Card can be connected with 32 sub-control keyboards and can support more than three levels of networking functions.

With a full Chinese and English menu, the functions of the matrix can be preset.

After the alarm, the camera and light can be automatically turned on, the preset point image can be automatically switched on and the video can be started.

The alarm mode of any zone can be set: regular, manual, regular/evacuation and inquiry alarm record.

The click output can be extended to 64 analog video output and the input can be extended to 512 analog video input.

The title of the cameras can be quickly inputted and managed by the King CY Character Input Software.


Product function:

Bah setting is flexible. It adopts plug-in card, modular and dense structure with exquisite raw materials. It has 16 input paths and 8 output paths.

Bah field control. Users can control the output of fixed or variable speed spherical cameras, panels, electric lenses, auxiliary relays, and 128 presets for each video input.

Bah system programming. The main keyboard of the system can be programmed through the screen menu. The CPU video output for programming can be directly connected to the monitor or controlled by switching/control system to display the monitor.


RS-485 communication and cascade. Compatible with 98% fast-ball protocols in China, support CY protocol, built-in 8 common protocols (PEL-D, PEL-P, Samsung fast-ball protocol), no additional protocol converter. Support multiple brand matrix cascade functions. There are several standard RS485/RS232 ports to communicate with keyboard, alarm interface unit, network system CPU, VCR control equipment, other interfaces, computers and so on. Data rates can be set for each port: 1200, 2400, 4800 or 9600 baud.


Choose an optional screen display. Each monitor can display date/time, video input number, user-defined video input or pre-positioned Title (16 characters), alarm title and monitor status. The system provides three date formats: MM/DD/YY, DD/MM/YY or YY/MM/DD. The screen display is in black and white. Users can set whether to display the following contents: video input number and monitor status, video input title and date/time. The control of display text includes horizontal/vertical movement and brightness.


Bah optional Man code communication. The board with RS232 interface can support 8 RJ45 multi-function connection modules, support TCP/IP, RS232, RS485, Man code communication protocol to achieve multi-function expansion.

Camera titles in English and Chinese. Matrix has Chinese and English character superposition function, supports Chinese character library, supports deep-viewing Chinese character input software, uses Japanese imported full-chip chip, character jitter-free. For each video input, the user can specify an 8-bit Chinese character number to replace the default video input number (e.g. a certain intersection). This can help operators distinguish video input, especially in high-rise buildings or networked systems.

Ba General Inspection. 64 patrols can be set up to call to the monitor at any time. Each Patrol has 64 video input locations, each of which also includes an independent dwell time, a preset target and an auxiliary contact action. The patrol can run forward or backward. The preset scene of the same video input and/or the same camera can be inserted into the patrol multiple times. Each patrol can be connected to form a sequence of more than 64 inputs. Video input that is not connected to the monitor will be automatically ignored.

Bah group switching. Group switching involves switching multiple video inputs to multiple continuous monitor outputs at the same time. Sixty-four independent group switching, each consisting of 16 video outputs (each with a preset bit and an auxiliary relay action), can be invoked manually or as part of a general patrol.

Automatic alarm call - 1024 alarm input. The alarm input can be programmed to switch any video input or group of video input to any one or more outputs. Each alarm input includes a target (preset scene), auxiliary contact action and residence time. Each video output can choose one of several alarm display/removal methods.

Bah alarm contact list. For alarm input number and monitor number, the camera image is invoked by programmed alarm contact list. Four alarm contact tables are programmable.

Bah alarm display mode. Users can choose alarm display mode for each video output.

Maintenance mode: display the first alarm until it is cleared, and then the alarms are queued in sequence.

(2) Sequential mode: sequential display of multiple alarms, each display for a certain time.

(3) Sequence and display: display the first alarm on a monitor until the alarm is cleared. Other alarms are displayed sequentially on the next monitor (all alarms are activated).

Bah alarm clearance mode. Users can define an alarm clearance method for each video output.

Confirmation: The alarm will be cleared only after the operator confirms the alarm manually.

(2) Automatic Clearance: Clear the alarm automatically 20 seconds after the alarm input stops (if there is no manual confirmation of the alarm).

Immediate automatic clearance: Clear the alarm immediately after the alarm stops (if the alarm has not been manually confirmed). As a safety measure, the alarm can not be confirmed manually at this time.

Systematic division. The channel permissions of keyboard, video input and video output are clearly defined, which further enhances the flexibility of the system. Channel permissions can restrict access to remote systems. The division of the system includes:

Keyboard to Monitor Channel: The selected keyboard cannot access the selected monitor.

Monitor to Camera Channel: The selected monitor cannot display the selected camera image.

(3) Keyboard to camera channel: The selected keyboard can not call or control the selected camera.

(4) Keyboard to camera control channel: The selected keyboard can not control the function of the selected camera scene.

Password and priority level. Keyboard or user can specify 16 levels to control the remote camera scene. The system can have up to 32 user passwords, each user has its own password. Restrict user's access rights according to user's priority level.

Choose computer workstations and networking. Single Edition Multimedia Suite (Including CD, CY Video Card, Digital-Analog Connector and Connector)


 

Technical parameters:

型号规格

 CY8000L  (参考型号:CY8000S,CY8000M)

视频输出

1-64路BNC接口

视频输入

1-512路BNC接口

音/视频指标

视频输入信号:    1Vp-p(75Ω)

视频输出信号:    1Vp-p(75Ω)

音频输入信号:    0.5Vp-p~5Vp-p(600Ω)

音频输出信号:    输入跟随

视频信噪比:      >70.5dB

音频信噪比:      >58dB

视频输入间隔离度:>55dB

视频输出间隔离度:>50dB

音频输入间隔离度:>58dB

音频输出间隔离度:>55dB

音频通道带宽:    50Hz~30KHz

视频通道带宽:    12MHz

切换属性

手动/编程自动全交叉无阻塞切换,具有单时序和群组切换功能

音/视频切换

同步切换

切换方式

采用电源同步切换

切换速度

PAL:≤20ms、NTSC:≤16.7ms

视频报警

有视频丢失检测报警功能

数据保存

内置存储器件,各种数据配置设置至少保存10年

数据通讯

多口RS485、RS232

屏幂显示

日期/时间、摄像机标题、报警信息等

图形叠加特性

突出显示,稳定、清晰、无跳动现象

图形输入方式

电脑编辑输入(CY文字图形画笔软件)

字符输入方式

CY字符输入软件

选配IP模块

以太网控制模块或1路视频服务器模块(可选)

环境条件

温度:-10℃ ~ +50℃,湿度: ≤90%(无冷凝)

尺寸

480mm(W) × 178mm(H) × 350mm(D)